Jung switch actuator Secure KNX UP![]()
XXX.XX
€/unit
Description • Nominal voltage: DC 21-32 V SELV • Switching current: 16 A For 230011SU: • Switching of electrical loads via relay contact • Reading of switching states of installation switches or buttons and other floating contacts at inputs 1-3 For 230021SU: • Switching of electrical loads via relay contacts with common reference potential • Switching of electrically operated blinds, roller shutters, awnings and similar • Ambient temperature: -5 ... +45°C • Dimensions (W x H x D): 48 x 50 x 28 mm • Commissioning mode: S-mode • KNX current consumption: 5 - 18 mA • KNX connection: Connection terminal on control line Outputs: • Connection type: Screw terminals • Screw terminals: AC 250 V ~ • Fluorescent lamps: 16 AX • Inrush current 200 µs: max. 800 A • Inrush current 20 ms: max. 165 A Connected load: • Ohmic load: 2500 W • Capacitive load: max. 16 A (140 µF) • Motors: 1380 VA • Incandescent lamps: 2300 W • HV Halogen lamps: 2300 W • HV LED lamps: max. 400 W • LV halogen lamps with: - Electronic transformers: 1500 W - Inductive transformers: 1200 VA • Compact fluorescent lamps: - Uncompensated: 1000 W - Parallel-compensated: 1160 W / 140 µF • Reduction in connected load: - Per 5°C exceeding 25°C: -10% - For installation in wooden or drywall: -15% - For installation in multiple combinations: -20% Connection: • Connection type: Screw terminals - Single-wire: 1 x 0.5 ... 4 mm² - Fine stranded without ferrule: 1 x 0.5 ... 4 mm² - Fine stranded with ferrule: 1 x 0.5 ... 2.5 mm² Inputs: • Control cable: YY6x0.6 (pre-assembled) • Input type: potential-free • Number: 3 • Total length of extension cable: max. 10 m • Cable type: J-Y(St)Y • Interrogation voltage extension inputs: approx. 5 V • Signal evaluation of condensation sensors (item no.: BTS 01) and leakage sensors (item no.: LES 01) at inputs 1...3 • Recording of temperature values via NTC temperature sensors (item no.: FF NTC, FF 7.8) at input 3 • Mounting in appliance box with dimensions according to DIN 49073 • Output can be operated via KNX telegrams or extension inputs • Three extension unit inputs for connecting potential-free contacts or condensation/leakage sensors. NTC temperature sensor can be connected to input 3 • Supply via bus, no additional supply voltage required • KNX Data Secure compatible from ETS 5.7.3 • Updateable with ETS Service app • Switch operation properties: - Normally open or normally closed operation - Logic operation and positive drive function - Central switching function - Time functions: Switch-on, switch-off delay, staircase light switch with pre-warning function - Scene function - Operating hours counter • Properties of extension unit input: - Operating functions Switches, Dimmers (incl. colour temperature dimming), blind control, value transmitter (1-byte, 2-byte, 3-byte and 6-byte incl. RGBW and colour temperature presets), scene extension unit etc. - Disable function - Debounce time adjustable • Logic properties: - Logic gate - Converter (conversion) - Blocking element - Comparator - Limit value switch • Blind operation properties: - Suitable for AC motors 110 ... 230 V - Operating modes "blind with slat", "roller shutter/awning", "ventilation flap/roof window" - Blind position and slat position directly controllable - Feedback of movement status, blind position and slat position - Forced position through higher-level control - Safety function: rain alarm, frost alarm, 3 independent wind alarms - Sun protection function with automatic heating/cooling function - Locking function (lock-out protection) Technical data
|
Products |