Jung switch actuator Secure KNX UP
XXX.XX
€/unit
Description • Nominal voltage: DC 21-32 V SELV • Switching current: 16 A For 230011SU: • Switching of electrical loads via relay contact • Reading of switching states of installation switches or buttons and other floating contacts at inputs 1-3 For 230021SU: • Switching of electrical loads via relay contacts with common reference potential • Switching of electrically operated blinds, roller shutters, awnings and similar • Ambient temperature: -5… +45°C • Dimensions (W x H x D): 48 x 50 x 28 mm • Commissioning mode: S-mode • Current consumption of KNX: 5 - 18 mA • KNX connection: Connection terminal for control cable Outputs: • Connection type: screw terminals • Screw terminals: AC 250 V ~ • Fluorescent lamps: 16 AX • Switching current 200 µs: max. 800 A • Switching current 20 ms: max. 165 A Connected load: • Ohmic load: 2500 W • Capacitive load: max. 16 A (140 µF) • Motors: 1380 VA • Bulbs: 2300 W • HV halogen lamps: 2300 W • HV-LED lamps: max. 400 W • LV halogen lamps with: - Electronic transformers: 1500 W - Inductive transformers: 1200 VA • Compact fluorescent lamps: - Uncompensated: 1000 W - Parallel-compensated: 1160 W / 140 µF • Reduction of connected load: - For every 5°C above 25°C: -10% - Installation in wood or drywall: -15% - Installation in multiple combinations: -20% Connection: • Connection type: screw terminals - Single wire: 1 x 0.5 ... 4 mm² - Fine wire without ferrule: 1 x 0.5 ... 4 mm² - Fine wire with ferrule: 1 x 0.5 ... 2.5 mm² Inputs: • Control cable: YY6x0.6 (pre-assembled) • Input type: floating • Number: 3 • Total length of extension unit cable: max. 10 m • Cable type: J-Y(St)Y • Voltage satellite inputs: approx. 5 V • Signal evaluation of dew formation sensors (art. no.: BTS 01) and leak sensors (art. no.: LES 01) at inputs 1...3 • Recording of temperature values via NTC temperature sensor (art. no.: FF NTC, FF 7.8) at input 3 • Assembly in device box with dimensions according to DIN 49073 • Output can be controlled via KNX telegrams or satellite inputs • Three satellite inputs for connection of floating contacts or dew formation/leak sensors NTC temperature sensor can be connected to input 3 • Power supply via bus, no additional power required • KNX Data Secure compatible from ETS 5.7.3 • Can be updated with ETS Service app • Switching mode properties - NO and NC contact operation - Linking and forced guidance functions - Central switching function - Time functions: Switch-on and switch-off delay, staircase light with advance warning function - Scene function - Operating hours counters • Characteristics of satellite input: - Operating functions switching, dimming (including colour temperature), controlling blinds, value transmitter (1 byte, 2 byte, 3 byte and 6 byte incl. RGBW und colour temperature pre-sets), scene extension etc. - Disabling function - Debounce time adjustable • Characteristics of logic: - Logic gates - Transformer (conversion) - Disabling element - Comparator - Limit value switch • Blind mode properties - Suitable for AC motors 110 ... 230 V - Operating modes “Slat blind”, “Roller shutter/awning”, “Ventilation flap/skylight” - Curtain position and slat position can be controlled directly - Feedback on movement status, curtain position and slat position - Forced position with higher level controller - Safety function: rain alarm, frost alarm, 3 independent wind alarms - Sun protection function with automatic heating-cooling • Disable function (lock-out protection) Technical data
|
Products |