Installation testing device Benning IT130 Ref no. 044103Order no.: 70 129 68
XXX.XX
€/unit
immediately available Description Application: • For electrical engineering, industry, photovoltaics • Testing of electrical systems in accordance with VDE 0100/0105 and IEC 60364 • All measurement functions can be selected directly via rotary switch General measurement functions: • Low ohmic resistance from protective conductor and potential equalisation conductor connectors (test current: 200 mA at IT 115 and IT 130 with reverse polarity) • Rotary field direction test in three-phase networks • True RMS measurement method for precise measurement results • Measuring function Specific: - Low-impedance resistance of protective conductor and equipotential bonding conductor connections (test current: 200 mA with polarity reversal) - Insulation resistance with test voltage of 50/100/250/500/1000 V - Loop impedance (L-PE) without RCD/RCD tripping and short-circuit current - Line impedance (L-N/L) with voltage drop and short-circuit current • Performance features: - Clear good/bad indication via green/red LED on the test device - Help function with connection diagram - Measured value memory over 4 levels: Object/block/fuse/measurement point - Bidirectional interfaces (USB/RS 232) - Upload of analogue structures and download of measured values - Integrated real-time clock (measured value with date/time) - "Commander test probe with test and Tanks button and LED measuring point lighting" - Connection for barcode scanner to identify the measuring point • Display: Graphic display (Lighting) • Low-resistance measurement: 0.01 Ω - 2 kΩ • Insulation resistance: 10 kΩ - 1000 MΩ • Line impedance (L-N/L): 0.01 Ω - 10 kΩ • Loop impedance (L-PE): 0.01 Ω - 10 kΩ • Short-circuit current: 0.01 A to 200 kA • RCD/RCD test: tripping time, tripping current (ramp), touch voltage, automatic test • RCD type: AC, A, F, and B/B+ • RCD/RCD current: 10/30/100/300/500/1000 mA • Phase sequence test: right/left in three-phase systems • Voltage: 1 V - 550 V • Frequency: 0 Hz - 500 Hz • Earthing resistance: 0.01 Ω - 2000 Ω (via earthing set) • Current: 0.1 mA - 400 A (via Pliers) • Illuminance: 0.01 lux - 20 klux (via sensor) • Measured value memory: up to 1800 measurement results • Scope of delivery: - Batteries: 6 x NiMH AA rechargeable batteries with charging function in the device + Chargers - Padded carrying case and shoulder strap - 3 Ladders test probe/crocodile clip set - Switchable commander test probe - PC software To product family Questions regarding itemPlease login beforehand Add to a listPlease login beforehand |
Products |