GIRA area/line coupler or line amplifier KNX REG
XXX.XX
€/unit
Description • The flush-mounted continuous controllers and the object controllers combine the functions of a bus coupler for KNX, a room temperature controller with specified setpoint value, and a binary input • Independent switching of max. two outputs • Ambient temperature: -5 to +45°C • Cable length • Inputs and outputs: max. 5 m • Temperature sensor: max. 50 m • Installation depth: 23 mm • Colour: pure white gloss • Four zero-voltage contacts can be connected to the binary input • Input 1 can be used to connect a remote sensor for temperature measurement in the floor • Two inputs can be configured as outputs (max. 0.8 mA) • The controller function is used for room temperature control. • The controller detects the current room temperature with an internal or external sensor and processes this with an adjustable temperature setpoint to create a correcting variable • Valve drives can be controlled with a constant adjustment signal or with a switching adjustment signal in this way • No separate bus coupler required • When connecting the external inputs, use of a switch terminal box is recommended Controller: • 5 operating modes: comfort, stand-by, night, frost or heat protection and controller lock (e.g. dew point operation) • Heating/cooling functions: heating, cooling, heating and cooling, basic and additional heating, basic and additional cooling • Pre-set control parameters for standard radiators and cooling units • Controller can be switched off (dew point mode) or the controller or controller interface can be locked • Valve protection function (valve is opened in a 24-hour cycle) • Control types: Continuous PI control, switching PI control (PWM) and switching 2-point control (on/off) • Temperature measurement via an internal and/or external sensor (average calculated for large rooms) Inputs: • Free assignment of the functions switching, dimming, blind and value transmitter to the inputs • Blocker for blocking individual inputs • Behaviour on return of bus voltage can be configured for each input • Telegram rate limitation • Precise details of scope of functions in the Gira online catalogue and technical device documentation Outputs: • Independent switching of max. two outputs • The temperature setpoint can be adjusted with the setting wheel • A presence button is used to switch between comfort and stand-by mode • The current statuses are displayed by LEDs on the continuous controller Technical data
|
Products |