Hager binary input KNX UP
XXX.XX
€/unit
Description • Protection type: IP20 • Operating voltage via bus: 21-32 V DC • For connection of floating contacts • Additionally for 62 142 32: - Two freely adjustable outputs for LED control • Input scanning voltage: 5 V per channel • Dimensions (L x W x H): 38 x 35 x 12 mm • Input voltage: 5 V • Max. line length to buttons: 5 mm • Operating temperature: 0 ... 45°C • Conductor cross-section (rigid): 0.75-2.5 mm² • Conductor cross-section (flexible): 0.75-2.5 mm² • Colour: light grey • With programming button and red programming LED • Switching, dimming, blind control, override, scene, heating and time switch functions • Integrated bus coupling • ETS additional functions: Value transmitter 1 and 2 byte, 2-channel mode, step switch function • Extension for light scene sensor • For flush-mounted and cavity wall fitting • Bus connection via terminals • Cable pre-assembled • For connection of floating contacts, such as switches, buttons, window contacts, detector contacts and temperature controllers, for communication with the KNX bus system • Two independent binary inputs for floating contacts Technical data
|
Products |